Coverart for item
The Resource Diagnostic biosensor polymers, Arthur M. Usmani, editor, Naim Akmal, editor

Diagnostic biosensor polymers, Arthur M. Usmani, editor, Naim Akmal, editor

Label
Diagnostic biosensor polymers
Title
Diagnostic biosensor polymers
Statement of responsibility
Arthur M. Usmani, editor, Naim Akmal, editor
Contributor
Subject
Genre
Language
eng
Member of
Cataloging source
DNLM/DLC
Illustrations
illustrations
Index
index present
Literary form
non fiction
Nature of contents
bibliography
http://library.link/vocab/relatedWorkOrContributorDate
  • 1940-
  • 1962-
  • 1993 :
http://library.link/vocab/relatedWorkOrContributorName
  • Usmani, Arthur M.
  • Akmal, Naim
  • American Chemical Society
Series statement
ACS symposium series
Series volume
556
http://library.link/vocab/subjectName
  • Biosensors
  • Polymers in medicine
  • Polymers
  • Piezoelectric polymer biosensors
  • Electrodes
  • Polymers
  • Biosensing Techniques
Label
Diagnostic biosensor polymers, Arthur M. Usmani, editor, Naim Akmal, editor
Instantiates
Publication
Note
"Developed from a symposium sponsored by the Division of Industrial and Engineering Chemistry, Inc., at the 205th National Meeting of the American Chemical Society, Denver, Colorado, March 28-April 2, 1993."
Bibliography note
Includes bibliographical references and indexes
Carrier category
volume
Carrier category code
  • nc
Carrier MARC source
rdacarrier
Content category
text
Content type code
  • txt
Content type MARC source
rdacontent
Contents
Diagnostic polymers and coatings : chemistry, technology, and applications / Arthur M. Usmani -- Fiber-optic sensors based on degradable polymers / Venetka Agayn and David R. Walt -- Enhancement of the stability of wired quinoprotein glucose dehydrogenase electrode / Ling Ye, Ioanis Katakis, Wolfgang Schuhmann, Hanns-Ludwig Schmidt, Johannis A. Duine, and Adam Heller -- Amperometric glucose-sensing electrodes with the use of modified enzymes / F. Mizutani, S. Yabuki, and T. Katsura -- Electron-transport rates in an enzyme electrode for glucose / Nigel A. Surridge, Eric R. Diebold, Julie Chang, and Gerold W. Neudeck -- Sandwich-type amperometric enzyme electrodes for determination of glucose / S. Mutlu, M. Mutlu, P. Vadgama, and E. Pişkin -- Reproducible electrodeposition technique for immobilizing glucose oxidase and a differentially permeable outer-membrane material for use on a miniature implantable glucose sensor / K.W. Johnson, D.J. Allen, J.J. Mastrototaro, R.J. Morff, and R.S. Nevin -- Thin-layer flow-through enzyme immunosensor based on polycaprolactam net / Lizhi Yin, Keli Xing, Hong Du, Hui Miao, Xi Wang, and Yuanming Li -- Conducting polymers and their application in amperometric biosensors / Wolfgang Schuhmann -- Poly(ether amine quinone)s as electron-transfer relay systems in amperometric glucose sensors / Hsing Lin Lan, T. Kaku, Hiroko I. Karan, and Yoshiyuki Okamoto -- Flow-injection analysis of some anionic species : automated, miniaturized, dual working electrode potentiostat using a poly(3-methylthiophene)-modified electrode / Elmo A. Blubaugh, George Russell, Merril Racke, Dwight Blubaugh, T.H. Ridgway, and H.B. Mark, Jr. -- Characterization of stability of modified poly(vinyl chloride) membranes for microfabricated ion-selective electrode arrays in biomedical applications / Ernö Lindner, Vasile V. Cosofret, Tal M. Nahir, and Richard P. Buck -- Biosensors based on ultrathin film composite membranes / Charles R. Martin, Barbara Ballarin, Charles Brumlik, and Del R. Lawson -- Viologen derivative containing polysiloxane as an electron-transfer mediator in amperometric glucose sensors / Hiroko I. Karan, Hsing Lin Lan, and Yoshiyuki Okamoto -- Hydrogen peroxide electrodes based on electrical connection of redox centers of various peroxidases to electrodes through a three-dimensional electron-relaying polymer network / Mark S. Vreeke and Adam Heller -- New biocompatible polymer : application for implantable glucose sensor / Kazuhiko Ishihara, Nobuo Nakabayashi, Kenro Nishida, Michiharu Sakakida, and Motoaki Shichiri -- Biocompatibility of perfluorosulfonic acid polymer membranes for biosensor applications / R.F.B. Turner and C.S. Sherwood -- Nondegradable and biodegradable polymeric particles : preparation and some selected biomedical applications / E. Pişkin, A. Tuncel, A. Denizli, E.B. Denkbaş, H. Ayhan, H. Çiçek, and K.T. Xu -- Semisynthetic macromolecular conjugates for biomimetic sensors / Mizuo Maeda, Koji Nakano, and Makoto Takagi -- Enzyme immobilization on polymerizable phospholipid assemblies / Alok Singh, Michael A. Markowitz, Li-I Tsao, and Jeffrey Deschamps -- Controlled release from liposomes of long-chain polymerizable diacetylenic phosphocholine and a short-chain saturated phospholipid / Michael A. Markowitz, Eddie L. Chang, and Alok Singh -- Immobilization of glucose oxidase on polyethylene film using a plasma-induced graft copolymerization process / Chee-Chan Wang and Ging-Ho Hsiue -- Spatially controlled on-wafer and on-chip enzyme immobilization using photochemical and electrochemical techniques / David J. Strike, Albert van den Berg, Nico F. de Rooij, and Milena Koudelka-Hep -- Electrical communication between glucose oxidase and electrodes based on poly(vinylimidazole) complex of bis(2,2'-bipyridine)-N, N'-dichloroosmium / Ravi Rajagopalan, Timothy J. Ohara, and Adam Heller
Control code
30078230
Dimensions
24 cm
Extent
xi, 330 pages
Isbn
9780841229082
Isbn Type
(alk. paper)
Lccn
94000895
Media category
unmediated
Media MARC source
rdamedia
Media type code
  • n
Other physical details
illustrations
System control number
(WaOLN)1633227
Label
Diagnostic biosensor polymers, Arthur M. Usmani, editor, Naim Akmal, editor
Publication
Note
"Developed from a symposium sponsored by the Division of Industrial and Engineering Chemistry, Inc., at the 205th National Meeting of the American Chemical Society, Denver, Colorado, March 28-April 2, 1993."
Bibliography note
Includes bibliographical references and indexes
Carrier category
volume
Carrier category code
  • nc
Carrier MARC source
rdacarrier
Content category
text
Content type code
  • txt
Content type MARC source
rdacontent
Contents
Diagnostic polymers and coatings : chemistry, technology, and applications / Arthur M. Usmani -- Fiber-optic sensors based on degradable polymers / Venetka Agayn and David R. Walt -- Enhancement of the stability of wired quinoprotein glucose dehydrogenase electrode / Ling Ye, Ioanis Katakis, Wolfgang Schuhmann, Hanns-Ludwig Schmidt, Johannis A. Duine, and Adam Heller -- Amperometric glucose-sensing electrodes with the use of modified enzymes / F. Mizutani, S. Yabuki, and T. Katsura -- Electron-transport rates in an enzyme electrode for glucose / Nigel A. Surridge, Eric R. Diebold, Julie Chang, and Gerold W. Neudeck -- Sandwich-type amperometric enzyme electrodes for determination of glucose / S. Mutlu, M. Mutlu, P. Vadgama, and E. Pişkin -- Reproducible electrodeposition technique for immobilizing glucose oxidase and a differentially permeable outer-membrane material for use on a miniature implantable glucose sensor / K.W. Johnson, D.J. Allen, J.J. Mastrototaro, R.J. Morff, and R.S. Nevin -- Thin-layer flow-through enzyme immunosensor based on polycaprolactam net / Lizhi Yin, Keli Xing, Hong Du, Hui Miao, Xi Wang, and Yuanming Li -- Conducting polymers and their application in amperometric biosensors / Wolfgang Schuhmann -- Poly(ether amine quinone)s as electron-transfer relay systems in amperometric glucose sensors / Hsing Lin Lan, T. Kaku, Hiroko I. Karan, and Yoshiyuki Okamoto -- Flow-injection analysis of some anionic species : automated, miniaturized, dual working electrode potentiostat using a poly(3-methylthiophene)-modified electrode / Elmo A. Blubaugh, George Russell, Merril Racke, Dwight Blubaugh, T.H. Ridgway, and H.B. Mark, Jr. -- Characterization of stability of modified poly(vinyl chloride) membranes for microfabricated ion-selective electrode arrays in biomedical applications / Ernö Lindner, Vasile V. Cosofret, Tal M. Nahir, and Richard P. Buck -- Biosensors based on ultrathin film composite membranes / Charles R. Martin, Barbara Ballarin, Charles Brumlik, and Del R. Lawson -- Viologen derivative containing polysiloxane as an electron-transfer mediator in amperometric glucose sensors / Hiroko I. Karan, Hsing Lin Lan, and Yoshiyuki Okamoto -- Hydrogen peroxide electrodes based on electrical connection of redox centers of various peroxidases to electrodes through a three-dimensional electron-relaying polymer network / Mark S. Vreeke and Adam Heller -- New biocompatible polymer : application for implantable glucose sensor / Kazuhiko Ishihara, Nobuo Nakabayashi, Kenro Nishida, Michiharu Sakakida, and Motoaki Shichiri -- Biocompatibility of perfluorosulfonic acid polymer membranes for biosensor applications / R.F.B. Turner and C.S. Sherwood -- Nondegradable and biodegradable polymeric particles : preparation and some selected biomedical applications / E. Pişkin, A. Tuncel, A. Denizli, E.B. Denkbaş, H. Ayhan, H. Çiçek, and K.T. Xu -- Semisynthetic macromolecular conjugates for biomimetic sensors / Mizuo Maeda, Koji Nakano, and Makoto Takagi -- Enzyme immobilization on polymerizable phospholipid assemblies / Alok Singh, Michael A. Markowitz, Li-I Tsao, and Jeffrey Deschamps -- Controlled release from liposomes of long-chain polymerizable diacetylenic phosphocholine and a short-chain saturated phospholipid / Michael A. Markowitz, Eddie L. Chang, and Alok Singh -- Immobilization of glucose oxidase on polyethylene film using a plasma-induced graft copolymerization process / Chee-Chan Wang and Ging-Ho Hsiue -- Spatially controlled on-wafer and on-chip enzyme immobilization using photochemical and electrochemical techniques / David J. Strike, Albert van den Berg, Nico F. de Rooij, and Milena Koudelka-Hep -- Electrical communication between glucose oxidase and electrodes based on poly(vinylimidazole) complex of bis(2,2'-bipyridine)-N, N'-dichloroosmium / Ravi Rajagopalan, Timothy J. Ohara, and Adam Heller
Control code
30078230
Dimensions
24 cm
Extent
xi, 330 pages
Isbn
9780841229082
Isbn Type
(alk. paper)
Lccn
94000895
Media category
unmediated
Media MARC source
rdamedia
Media type code
  • n
Other physical details
illustrations
System control number
(WaOLN)1633227

Library Locations

    • Curtis Laws Wilson LibraryBorrow it
      400 West 14th Street, Rolla, MO, 65409, US
      37.955220 -91.772210
Processing Feedback ...