Coverart for item
The Resource Metal-on-metal total hip replacement devices, editors, Steven M. Kurtz, A. Seth Greenwald, William M. Mihalko, Jack E. Lemons, (electronic resource)

Metal-on-metal total hip replacement devices, editors, Steven M. Kurtz, A. Seth Greenwald, William M. Mihalko, Jack E. Lemons, (electronic resource)

Label
Metal-on-metal total hip replacement devices
Title
Metal-on-metal total hip replacement devices
Statement of responsibility
editors, Steven M. Kurtz, A. Seth Greenwald, William M. Mihalko, Jack E. Lemons
Creator
Contributor
Subject
Language
eng
Member of
Cataloging source
DNLM
http://bibfra.me/vocab/lite/meetingDate
2012
http://bibfra.me/vocab/lite/meetingName
Symposium on Metal-On-Metal Total Hip Replacement Devices
NLM call number
  • 2014 H-525
  • WE 860
http://library.link/vocab/relatedWorkOrContributorDate
1968-
http://library.link/vocab/relatedWorkOrContributorName
  • Kurtz, Steven M.
  • Greenwald, A. Seth
  • Mihalko, William M
  • Lemons, Jack E
  • ASTM International
Series statement
Selected technical papers
Series volume
STP1560
http://library.link/vocab/subjectName
  • Arthroplasty, Replacement, Hip
  • Equipment Failure Analysis
  • Hip Prosthesis
  • Metal-on-Metal Joint Prostheses
  • Metal-on-Metal Joint Prostheses
Label
Metal-on-metal total hip replacement devices, editors, Steven M. Kurtz, A. Seth Greenwald, William M. Mihalko, Jack E. Lemons, (electronic resource)
Instantiates
Publication
Bibliography note
Includes bibliographical references and indexes
Contents
  • Prevalence of metal-on-metal bearings in the United States / S.M. Kurtz, K.L. Ong, E. Lau, A.S. Greenwald, and K. Bozic -- Metal-on-metal and other bearing trends among fellows of the AAOS / K.L. Urish, M. Amini, and W.M. Mihalko -- Risk of complications, revision, and cancer for metal-on-metal patients in the medicare population / K.L. Ong, E. Lau, and S.M. Kurtz -- Serum metal ion concentrations decline (but do not rapidly normalize) following revision of metal-on-metal total hip bearings / J.A. Browne, Z. Wan, W.M. Novicoff, Q. Cui, and T.E. Brown -- Low cobalt and chromium levels from a single metal-on-metal total hip arthroplasty implant / A.F. Chen, M.T. Pigott, E.J. McClain, and B.A. Klatt -- A prospective case series examining the use of a large-head metal-on-metal total hip system / V. Chatrath, I. Catelas, and P.E. Beaule -- A method to isolate and characterize wear debris from synovial fluid and tissues / A.E. Kavanaugh, P. Benya, and F. Billi -- Lymphocyte reactivity to nickel correlates with reported high-pain levels in patients with total joint arthroplasties : implications for pain-related hypersensitivity responses / M.S. Caicedo, L. Samelko, and N.J. Hallab -- Approach, rationale, and examples of metal-on-metal device retrieval and analysis for evidence-based education / J. Lemons, D. Sarver, P. Beck, D. Petersen, and A. Eberhardt -- The development of a standard method for assessing wear of explanted metal-on-metal hip joints / R.J. Underwood, M. Fowell, R. Sayles, S.M. Kurtz, and P. Cann -- Method of characterizing fretting and corrosion at the various taper connections of retrieved modular components from metal-on-metal total hip arthroplasty / G.B. Higgs, J.A. Hanzlik, D.W. MacDonald, W.M. Kane, J.S. Day, G.R. Klein, J. Parvizi, M.A. Mont, M.J. Kraay, J.M. Martell, J.L. Gilbert, C.M. Rimnac, and S.M. Kurtz -- Normal and adverse wear patterns created in-vivo on metal-on-metal surfaces : a retrieval study representing four vendors / I.C. Clarke, T.K. Donaldson, M.D. Burgett, E.J. Smith, J. Bowsher, C. Savisaar, A. John, J.Y. Lazennec, E. Mcpherson, and C.L. Peters -- Analysis of comprehensive measurements from retrieved implants to determine factors contributing to failure modes and wear / P. Campbell, E. Ebramzadeh, S. Azad, F. Billi, Z. Lu, and H. McKellop -- A protocol to assess the wear of head/neck taper junctions in large head metal-on-metal (LHMoM) hips / R.J. Underwood, S.B. Kocagoz, R. Smith, R.S. Sayles, R. Siskey, S.M. Kurtz, and P.M. Cann -- Plastic deformation from edge loading is common on retrieved metal-on-metal hips and can be predicted with finite element analysis / D. McHugh, J. Currier, F. Kennedy, J. Collier, and D. Van Citters -- Microstructure of retrievals made from standard cast HC-CoCrMo alloys / P. Stemmer, R. Pourzal, Y. Liao, L. Marks, M. Morlock, J.J. Jacobs, M.A. Wimmer, and A. Fischer -- Development of a stop-dwell-start (SDS) protocol for in vitro wear testing of metal-on-metal total hip replacements / M. Hadley, C. Hardaker, S. Williams, Z. Jin, G. Isaac, and J. Fisher -- Tribochemical reactions in metal-on-metal hip joints influence wear and corrosion / M.A. Wimmer, M.T. Mathew, M.P. Laurent, C. Nagelli, Y. Liao, L.D. Marks, R. Pourzal, A. Fischer, and J.J. Jacobs -- Denatured protein deposits identified on simulator and explant hip bearings / M. Burgett, T. Donaldson, I.C. Clarke, C. Savisaar, and J. Bowsher -- Study on tribological and electrochemical performance of metal artificial hip joint materials in simulated synovial fluids / Z.K. Hua, G. Mcknight, and J. McCloy
  • Prevalence of metal-on-metal bearings in the United States / S.M. Kurtz, K.L. Ong, E. Lau, A.S. Greenwald, and K. Bozic -- Metal-on-metal and other bearing trends among fellows of the AAOS / K.L. Urish, M. Amini, and W.M. Mihalko -- Risk of complications, revision, and cancer for metal-on-metal patients in the medicare population / K.L. Ong, E. Lau, and S.M. Kurtz -- Serum metal ion concentrations decline (but do not rapidly normalize) following revision of metal-on-metal total hip bearings / J.A. Browne, Z. Wan, W.M. Novicoff, Q. Cui, and T.E. Brown -- Low cobalt and chromium levels from a single metal-on-metal total hip arthroplasty implant / A.F. Chen, M.T. Pigott, E.J. McClain, and B.A. Klatt -- A prospective case series examining the use of a large-head metal-on-metal total hip system / V. Chatrath, I. Catelas, and P.E. Beaule -- A method to isolate and characterize wear debris from synovial fluid and tissues / A.E. Kavanaugh, P. Benya, and F. Billi -- Lymphocyte reactivity to nickel correlates with reported high-pain levels in patients with total joint arthroplasties : implications for pain-related hypersensitivity responses / M.S. Caicedo, L. Samelko, and N.J. Hallab -- Approach, rationale, and examples of metal-on-metal device retrieval and analysis for evidence-based education / J. Lemons, D. Sarver, P. Beck, D. Petersen, and A. Eberhardt -- The development of a standard method for assessing wear of explanted metal-on-metal hip joints / R.J. Underwood, M. Fowell, R. Sayles, S.M. Kurtz, and P. Cann -- Method of characterizing fretting and corrosion at the various taper connections of retrieved modular components from metal-on-metal total hip arthroplasty / G.B. Higgs, J.A. Hanzlik, D.W. MacDonald, W.M. Kane, J.S. Day, G.R. Klein, J. Parvizi, M.A. Mont, M.J. Kraay, J.M. Martell, J.L. Gilbert, C.M. Rimnac, and S.M. Kurtz -- Normal and adverse wear patterns created in-vivo on metal-on-metal surfaces : a retrieval study representing four vendors / I.C. Clarke, T.K. Donaldson, M.D. Burgett, E.J. Smith, J. Bowsher, C. Savisaar, A. John, J.Y. Lazennec, E. Mcpherson, and C.L. Peters -- Analysis of comprehensive measurements from retrieved implants to determine factors contributing to failure modes and wear / P. Campbell, E. Ebramzadeh, S. Azad, F. Billi, Z. Lu, and H. McKellop -- A protocol to assess the wear of head/neck taper junctions in large head metal-on-metal (LHMoM) hips / R.J. Underwood, S.B. Kocagoz, R. Smith, R.S. Sayles, R. Siskey, S.M. Kurtz, and P.M. Cann -- Plastic deformation from edge loading is common on retrieved metal-on-metal hips and can be predicted with finite element analysis / D. McHugh, J. Currier, F. Kennedy, J. Collier, and D. Van Citters -- Microstructure of retrievals made from standard cast HC-CoCrMo alloys / P. Stemmer, R. Pourzal, Y. Liao, L. Marks, M. Morlock, J.J. Jacobs, M.A. Wimmer, and A. Fischer -- Development of a stop-dwell-start (SDS) protocol for in vitro wear testing of metal-on-metal total hip replacements / M. Hadley, C. Hardaker, S. Williams, Z. Jin, G. Isaac, and J. Fisher -- Tribochemical reactions in metal-on-metal hip joints influence wear and corrosion / M.A. Wimmer, M.T. Mathew, M.P. Laurent, C. Nagelli, Y. Liao, L.D. Marks, R. Pourzal, A. Fischer, and J.J. Jacobs -- Denatured protein deposits identified on simulator and explant hip bearings / M. Burgett, T. Donaldson, I.C. Clarke, C. Savisaar, and J. Bowsher -- Study on tribological and electrochemical performance of metal artificial hip joint materials in simulated synovial fluids / Z.K. Hua, G. Mcknight, and J. McCloy
  • Prevalence of metal-on-metal bearings in the United States / S.M. Kurtz, K.L. Ong, E. Lau, A.S. Greenwald, and K. Bozic -- Metal-on-metal and other bearing trends among fellows of the AAOS / K.L. Urish, M. Amini, and W.M. Mihalko -- Risk of complications, revision, and cancer for metal-on-metal patients in the medicare population / K.L. Ong, E. Lau, and S.M. Kurtz -- Serum metal ion concentrations decline (but do not rapidly normalize) following revision of metal-on-metal total hip bearings / J.A. Browne, Z. Wan, W.M. Novicoff, Q. Cui, and T.E. Brown -- Low cobalt and chromium levels from a single metal-on-metal total hip arthroplasty implant / A.F. Chen, M.T. Pigott, E.J. McClain, and B.A. Klatt -- A prospective case series examining the use of a large-head metal-on-metal total hip system / V. Chatrath, I. Catelas, and P.E. Beaule -- A method to isolate and characterize wear debris from synovial fluid and tissues / A.E. Kavanaugh, P. Benya, and F. Billi -- Lymphocyte reactivity to nickel correlates with reported high-pain levels in patients with total joint arthroplasties : implications for pain-related hypersensitivity responses / M.S. Caicedo, L. Samelko, and N.J. Hallab -- Approach, rationale, and examples of metal-on-metal device retrieval and analysis for evidence-based education / J. Lemons, D. Sarver, P. Beck, D. Petersen, and A. Eberhardt -- The development of a standard method for assessing wear of explanted metal-on-metal hip joints / R.J. Underwood, M. Fowell, R. Sayles, S.M. Kurtz, and P. Cann -- Method of characterizing fretting and corrosion at the various taper connections of retrieved modular components from metal-on-metal total hip arthroplasty / G.B. Higgs, J.A. Hanzlik, D.W. MacDonald, W.M. Kane, J.S. Day, G.R. Klein, J. Parvizi, M.A. Mont, M.J. Kraay, J.M. Martell, J.L. Gilbert, C.M. Rimnac, and S.M. Kurtz -- Normal and adverse wear patterns created in-vivo on metal-on-metal surfaces : a retrieval study representing four vendors / I.C. Clarke, T.K. Donaldson, M.D. Burgett, E.J. Smith, J. Bowsher, C. Savisaar, A. John, J.Y. Lazennec, E. Mcpherson, and C.L. Peters -- Analysis of comprehensive measurements from retrieved implants to determine factors contributing to failure modes and wear / P. Campbell, E. Ebramzadeh, S. Azad, F. Billi, Z. Lu, and H. McKellop -- A protocol to assess the wear of head/neck taper junctions in large head metal-on-metal (LHMoM) hips / R.J. Underwood, S.B. Kocagoz, R. Smith, R.S. Sayles, R. Siskey, S.M. Kurtz, and P.M. Cann -- Plastic deformation from edge loading is common on retrieved metal-on-metal hips and can be predicted with finite element analysis / D. McHugh, J. Currier, F. Kennedy, J. Collier, and D. Van Citters -- Microstructure of retrievals made from standard cast HC-CoCrMo alloys / P. Stemmer, R. Pourzal, Y. Liao, L. Marks, M. Morlock, J.J. Jacobs, M.A. Wimmer, and A. Fischer -- Development of a stop-dwell-start (SDS) protocol for in vitro wear testing of metal-on-metal total hip replacements / M. Hadley, C. Hardaker, S. Williams, Z. Jin, G. Isaac, and J. Fisher -- Tribochemical reactions in metal-on-metal hip joints influence wear and corrosion / M.A. Wimmer, M.T. Mathew, M.P. Laurent, C. Nagelli, Y. Liao, L.D. Marks, R. Pourzal, A. Fischer, and J.J. Jacobs -- Denatured protein deposits identified on simulator and explant hip bearings / M. Burgett, T. Donaldson, I.C. Clarke, C. Savisaar, and J. Bowsher -- Study on tribological and electrochemical performance of metal artificial hip joint materials in simulated synovial fluids / Z.K. Hua, G. Mcknight, and J. McCloy
  • Prevalence of metal-on-metal bearings in the United States / S.M. Kurtz, K.L. Ong, E. Lau, A.S. Greenwald, and K. Bozic -- Metal-on-metal and other bearing trends among fellows of the AAOS / K.L. Urish, M. Amini, and W.M. Mihalko -- Risk of complications, revision, and cancer for metal-on-metal patients in the medicare population / K.L. Ong, E. Lau, and S.M. Kurtz -- Serum metal ion concentrations decline (but do not rapidly normalize) following revision of metal-on-metal total hip bearings / J.A. Browne, Z. Wan, W.M. Novicoff, Q. Cui, and T.E. Brown -- Low cobalt and chromium levels from a single metal-on-metal total hip arthroplasty implant / A.F. Chen, M.T. Pigott, E.J. McClain, and B.A. Klatt -- A prospective case series examining the use of a large-head metal-on-metal total hip system / V. Chatrath, I. Catelas, and P.E. Beaule -- A method to isolate and characterize wear debris from synovial fluid and tissues / A.E. Kavanaugh, P. Benya, and F. Billi -- Lymphocyte reactivity to nickel correlates with reported high-pain levels in patients with total joint arthroplasties : implications for pain-related hypersensitivity responses / M.S. Caicedo, L. Samelko, and N.J. Hallab -- Approach, rationale, and examples of metal-on-metal device retrieval and analysis for evidence-based education / J. Lemons, D. Sarver, P. Beck, D. Petersen, and A. Eberhardt -- The development of a standard method for assessing wear of explanted metal-on-metal hip joints / R.J. Underwood, M. Fowell, R. Sayles, S.M. Kurtz, and P. Cann -- Method of characterizing fretting and corrosion at the various taper connections of retrieved modular components from metal-on-metal total hip arthroplasty / G.B. Higgs, J.A. Hanzlik, D.W. MacDonald, W.M. Kane, J.S. Day, G.R. Klein, J. Parvizi, M.A. Mont, M.J. Kraay, J.M. Martell, J.L. Gilbert, C.M. Rimnac, and S.M. Kurtz -- Normal and adverse wear patterns created in-vivo on metal-on-metal surfaces : a retrieval study representing four vendors / I.C. Clarke, T.K. Donaldson, M.D. Burgett, E.J. Smith, J. Bowsher, C. Savisaar, A. John, J.Y. Lazennec, E. Mcpherson, and C.L. Peters -- Analysis of comprehensive measurements from retrieved implants to determine factors contributing to failure modes and wear / P. Campbell, E. Ebramzadeh, S. Azad, F. Billi, Z. Lu, and H. McKellop -- A protocol to assess the wear of head/neck taper junctions in large head metal-on-metal (LHMoM) hips / R.J. Underwood, S.B. Kocagoz, R. Smith, R.S. Sayles, R. Siskey, S.M. Kurtz, and P.M. Cann -- Plastic deformation from edge loading is common on retrieved metal-on-metal hips and can be predicted with finite element analysis / D. McHugh, J. Currier, F. Kennedy, J. Collier, and D. Van Citters -- Microstructure of retrievals made from standard cast HC-CoCrMo alloys / P. Stemmer, R. Pourzal, Y. Liao, L. Marks, M. Morlock, J.J. Jacobs, M.A. Wimmer, and A. Fischer -- Development of a stop-dwell-start (SDS) protocol for in vitro wear testing of metal-on-metal total hip replacements / M. Hadley, C. Hardaker, S. Williams, Z. Jin, G. Isaac, and J. Fisher -- Tribochemical reactions in metal-on-metal hip joints influence wear and corrosion / M.A. Wimmer, M.T. Mathew, M.P. Laurent, C. Nagelli, Y. Liao, L.D. Marks, R. Pourzal, A. Fischer, and J.J. Jacobs -- Denatured protein deposits identified on simulator and explant hip bearings / M. Burgett, T. Donaldson, I.C. Clarke, C. Savisaar, and J. Bowsher -- Study on tribological and electrochemical performance of metal artificial hip joint materials in simulated synovial fluids / Z.K. Hua, G. Mcknight, and J. McCloy
  • Prevalence of metal-on-metal bearings in the United States / S.M. Kurtz, K.L. Ong, E. Lau, A.S. Greenwald, and K. Bozic -- Metal-on-metal and other bearing trends among fellows of the AAOS / K.L. Urish, M. Amini, and W.M. Mihalko -- Risk of complications, revision, and cancer for metal-on-metal patients in the medicare population / K.L. Ong, E. Lau, and S.M. Kurtz -- Serum metal ion concentrations decline (but do not rapidly normalize) following revision of metal-on-metal total hip bearings / J.A. Browne, Z. Wan, W.M. Novicoff, Q. Cui, and T.E. Brown -- Low cobalt and chromium levels from a single metal-on-metal total hip arthroplasty implant / A.F. Chen, M.T. Pigott, E.J. McClain, and B.A. Klatt -- A prospective case series examining the use of a large-head metal-on-metal total hip system / V. Chatrath, I. Catelas, and P.E. Beaule -- A method to isolate and characterize wear debris from synovial fluid and tissues / A.E. Kavanaugh, P. Benya, and F. Billi -- Lymphocyte reactivity to nickel correlates with reported high-pain levels in patients with total joint arthroplasties : implications for pain-related hypersensitivity responses / M.S. Caicedo, L. Samelko, and N.J. Hallab -- Approach, rationale, and examples of metal-on-metal device retrieval and analysis for evidence-based education / J. Lemons, D. Sarver, P. Beck, D. Petersen, and A. Eberhardt -- The development of a standard method for assessing wear of explanted metal-on-metal hip joints / R.J. Underwood, M. Fowell, R. Sayles, S.M. Kurtz, and P. Cann -- Method of characterizing fretting and corrosion at the various taper connections of retrieved modular components from metal-on-metal total hip arthroplasty / G.B. Higgs, J.A. Hanzlik, D.W. MacDonald, W.M. Kane, J.S. Day, G.R. Klein, J. Parvizi, M.A. Mont, M.J. Kraay, J.M. Martell, J.L. Gilbert, C.M. Rimnac, and S.M. Kurtz -- Normal and adverse wear patterns created in-vivo on metal-on-metal surfaces : a retrieval study representing four vendors / I.C. Clarke, T.K. Donaldson, M.D. Burgett, E.J. Smith, J. Bowsher, C. Savisaar, A. John, J.Y. Lazennec, E. Mcpherson, and C.L. Peters -- Analysis of comprehensive measurements from retrieved implants to determine factors contributing to failure modes and wear / P. Campbell, E. Ebramzadeh, S. Azad, F. Billi, Z. Lu, and H. McKellop -- A protocol to assess the wear of head/neck taper junctions in large head metal-on-metal (LHMoM) hips / R.J. Underwood, S.B. Kocagoz, R. Smith, R.S. Sayles, R. Siskey, S.M. Kurtz, and P.M. Cann -- Plastic deformation from edge loading is common on retrieved metal-on-metal hips and can be predicted with finite element analysis / D. McHugh, J. Currier, F. Kennedy, J. Collier, and D. Van Citters -- Microstructure of retrievals made from standard cast HC-CoCrMo alloys / P. Stemmer, R. Pourzal, Y. Liao, L. Marks, M. Morlock, J.J. Jacobs, M.A. Wimmer, and A. Fischer -- Development of a stop-dwell-start (SDS) protocol for in vitro wear testing of metal-on-metal total hip replacements / M. Hadley, C. Hardaker, S. Williams, Z. Jin, G. Isaac, and J. Fisher -- Tribochemical reactions in metal-on-metal hip joints influence wear and corrosion / M.A. Wimmer, M.T. Mathew, M.P. Laurent, C. Nagelli, Y. Liao, L.D. Marks, R. Pourzal, A. Fischer, and J.J. Jacobs -- Denatured protein deposits identified on simulator and explant hip bearings / M. Burgett, T. Donaldson, I.C. Clarke, C. Savisaar, and J. Bowsher -- Study on tribological and electrochemical performance of metal artificial hip joint materials in simulated synovial fluids / Z.K. Hua, G. Mcknight, and J. McCloy
  • Prevalence of metal-on-metal bearings in the United States / S.M. Kurtz, K.L. Ong, E. Lau, A.S. Greenwald, and K. Bozic -- Metal-on-metal and other bearing trends among fellows of the AAOS / K.L. Urish, M. Amini, and W.M. Mihalko -- Risk of complications, revision, and cancer for metal-on-metal patients in the medicare population / K.L. Ong, E. Lau, and S.M. Kurtz -- Serum metal ion concentrations decline (but do not rapidly normalize) following revision of metal-on-metal total hip bearings / J.A. Browne, Z. Wan, W.M. Novicoff, Q. Cui, and T.E. Brown -- Low cobalt and chromium levels from a single metal-on-metal total hip arthroplasty implant / A.F. Chen, M.T. Pigott, E.J. McClain, and B.A. Klatt -- A prospective case series examining the use of a large-head metal-on-metal total hip system / V. Chatrath, I. Catelas, and P.E. Beaule -- A method to isolate and characterize wear debris from synovial fluid and tissues / A.E. Kavanaugh, P. Benya, and F. Billi -- Lymphocyte reactivity to nickel correlates with reported high-pain levels in patients with total joint arthroplasties : implications for pain-related hypersensitivity responses / M.S. Caicedo, L. Samelko, and N.J. Hallab -- Approach, rationale, and examples of metal-on-metal device retrieval and analysis for evidence-based education / J. Lemons, D. Sarver, P. Beck, D. Petersen, and A. Eberhardt -- The development of a standard method for assessing wear of explanted metal-on-metal hip joints / R.J. Underwood, M. Fowell, R. Sayles, S.M. Kurtz, and P. Cann -- Method of characterizing fretting and corrosion at the various taper connections of retrieved modular components from metal-on-metal total hip arthroplasty / G.B. Higgs, J.A. Hanzlik, D.W. MacDonald, W.M. Kane, J.S. Day, G.R. Klein, J. Parvizi, M.A. Mont, M.J. Kraay, J.M. Martell, J.L. Gilbert, C.M. Rimnac, and S.M. Kurtz -- Normal and adverse wear patterns created in-vivo on metal-on-metal surfaces : a retrieval study representing four vendors / I.C. Clarke, T.K. Donaldson, M.D. Burgett, E.J. Smith, J. Bowsher, C. Savisaar, A. John, J.Y. Lazennec, E. Mcpherson, and C.L. Peters -- Analysis of comprehensive measurements from retrieved implants to determine factors contributing to failure modes and wear / P. Campbell, E. Ebramzadeh, S. Azad, F. Billi, Z. Lu, and H. McKellop -- A protocol to assess the wear of head/neck taper junctions in large head metal-on-metal (LHMoM) hips / R.J. Underwood, S.B. Kocagoz, R. Smith, R.S. Sayles, R. Siskey, S.M. Kurtz, and P.M. Cann -- Plastic deformation from edge loading is common on retrieved metal-on-metal hips and can be predicted with finite element analysis / D. McHugh, J. Currier, F. Kennedy, J. Collier, and D. Van Citters -- Microstructure of retrievals made from standard cast HC-CoCrMo alloys / P. Stemmer, R. Pourzal, Y. Liao, L. Marks, M. Morlock, J.J. Jacobs, M.A. Wimmer, and A. Fischer -- Development of a stop-dwell-start (SDS) protocol for in vitro wear testing of metal-on-metal total hip replacements / M. Hadley, C. Hardaker, S. Williams, Z. Jin, G. Isaac, and J. Fisher -- Tribochemical reactions in metal-on-metal hip joints influence wear and corrosion / M.A. Wimmer, M.T. Mathew, M.P. Laurent, C. Nagelli, Y. Liao, L.D. Marks, R. Pourzal, A. Fischer, and J.J. Jacobs -- Denatured protein deposits identified on simulator and explant hip bearings / M. Burgett, T. Donaldson, I.C. Clarke, C. Savisaar, and J. Bowsher -- Study on tribological and electrochemical performance of metal artificial hip joint materials in simulated synovial fluids / Z.K. Hua, G. Mcknight, and J. McCloy
Control code
OCM1bookssj0001184290
Dimensions
unknown
Isbn
9780803175464
Isbn Type
(alk. paper)
Lccn
2013023318
Specific material designation
remote
System control number
(WaSeSS)bookssj0001184290
Label
Metal-on-metal total hip replacement devices, editors, Steven M. Kurtz, A. Seth Greenwald, William M. Mihalko, Jack E. Lemons, (electronic resource)
Publication
Bibliography note
Includes bibliographical references and indexes
Contents
  • Prevalence of metal-on-metal bearings in the United States / S.M. Kurtz, K.L. Ong, E. Lau, A.S. Greenwald, and K. Bozic -- Metal-on-metal and other bearing trends among fellows of the AAOS / K.L. Urish, M. Amini, and W.M. Mihalko -- Risk of complications, revision, and cancer for metal-on-metal patients in the medicare population / K.L. Ong, E. Lau, and S.M. Kurtz -- Serum metal ion concentrations decline (but do not rapidly normalize) following revision of metal-on-metal total hip bearings / J.A. Browne, Z. Wan, W.M. Novicoff, Q. Cui, and T.E. Brown -- Low cobalt and chromium levels from a single metal-on-metal total hip arthroplasty implant / A.F. Chen, M.T. Pigott, E.J. McClain, and B.A. Klatt -- A prospective case series examining the use of a large-head metal-on-metal total hip system / V. Chatrath, I. Catelas, and P.E. Beaule -- A method to isolate and characterize wear debris from synovial fluid and tissues / A.E. Kavanaugh, P. Benya, and F. Billi -- Lymphocyte reactivity to nickel correlates with reported high-pain levels in patients with total joint arthroplasties : implications for pain-related hypersensitivity responses / M.S. Caicedo, L. Samelko, and N.J. Hallab -- Approach, rationale, and examples of metal-on-metal device retrieval and analysis for evidence-based education / J. Lemons, D. Sarver, P. Beck, D. Petersen, and A. Eberhardt -- The development of a standard method for assessing wear of explanted metal-on-metal hip joints / R.J. Underwood, M. Fowell, R. Sayles, S.M. Kurtz, and P. Cann -- Method of characterizing fretting and corrosion at the various taper connections of retrieved modular components from metal-on-metal total hip arthroplasty / G.B. Higgs, J.A. Hanzlik, D.W. MacDonald, W.M. Kane, J.S. Day, G.R. Klein, J. Parvizi, M.A. Mont, M.J. Kraay, J.M. Martell, J.L. Gilbert, C.M. Rimnac, and S.M. Kurtz -- Normal and adverse wear patterns created in-vivo on metal-on-metal surfaces : a retrieval study representing four vendors / I.C. Clarke, T.K. Donaldson, M.D. Burgett, E.J. Smith, J. Bowsher, C. Savisaar, A. John, J.Y. Lazennec, E. Mcpherson, and C.L. Peters -- Analysis of comprehensive measurements from retrieved implants to determine factors contributing to failure modes and wear / P. Campbell, E. Ebramzadeh, S. Azad, F. Billi, Z. Lu, and H. McKellop -- A protocol to assess the wear of head/neck taper junctions in large head metal-on-metal (LHMoM) hips / R.J. Underwood, S.B. Kocagoz, R. Smith, R.S. Sayles, R. Siskey, S.M. Kurtz, and P.M. Cann -- Plastic deformation from edge loading is common on retrieved metal-on-metal hips and can be predicted with finite element analysis / D. McHugh, J. Currier, F. Kennedy, J. Collier, and D. Van Citters -- Microstructure of retrievals made from standard cast HC-CoCrMo alloys / P. Stemmer, R. Pourzal, Y. Liao, L. Marks, M. Morlock, J.J. Jacobs, M.A. Wimmer, and A. Fischer -- Development of a stop-dwell-start (SDS) protocol for in vitro wear testing of metal-on-metal total hip replacements / M. Hadley, C. Hardaker, S. Williams, Z. Jin, G. Isaac, and J. Fisher -- Tribochemical reactions in metal-on-metal hip joints influence wear and corrosion / M.A. Wimmer, M.T. Mathew, M.P. Laurent, C. Nagelli, Y. Liao, L.D. Marks, R. Pourzal, A. Fischer, and J.J. Jacobs -- Denatured protein deposits identified on simulator and explant hip bearings / M. Burgett, T. Donaldson, I.C. Clarke, C. Savisaar, and J. Bowsher -- Study on tribological and electrochemical performance of metal artificial hip joint materials in simulated synovial fluids / Z.K. Hua, G. Mcknight, and J. McCloy
  • Prevalence of metal-on-metal bearings in the United States / S.M. Kurtz, K.L. Ong, E. Lau, A.S. Greenwald, and K. Bozic -- Metal-on-metal and other bearing trends among fellows of the AAOS / K.L. Urish, M. Amini, and W.M. Mihalko -- Risk of complications, revision, and cancer for metal-on-metal patients in the medicare population / K.L. Ong, E. Lau, and S.M. Kurtz -- Serum metal ion concentrations decline (but do not rapidly normalize) following revision of metal-on-metal total hip bearings / J.A. Browne, Z. Wan, W.M. Novicoff, Q. Cui, and T.E. Brown -- Low cobalt and chromium levels from a single metal-on-metal total hip arthroplasty implant / A.F. Chen, M.T. Pigott, E.J. McClain, and B.A. Klatt -- A prospective case series examining the use of a large-head metal-on-metal total hip system / V. Chatrath, I. Catelas, and P.E. Beaule -- A method to isolate and characterize wear debris from synovial fluid and tissues / A.E. Kavanaugh, P. Benya, and F. Billi -- Lymphocyte reactivity to nickel correlates with reported high-pain levels in patients with total joint arthroplasties : implications for pain-related hypersensitivity responses / M.S. Caicedo, L. Samelko, and N.J. Hallab -- Approach, rationale, and examples of metal-on-metal device retrieval and analysis for evidence-based education / J. Lemons, D. Sarver, P. Beck, D. Petersen, and A. Eberhardt -- The development of a standard method for assessing wear of explanted metal-on-metal hip joints / R.J. Underwood, M. Fowell, R. Sayles, S.M. Kurtz, and P. Cann -- Method of characterizing fretting and corrosion at the various taper connections of retrieved modular components from metal-on-metal total hip arthroplasty / G.B. Higgs, J.A. Hanzlik, D.W. MacDonald, W.M. Kane, J.S. Day, G.R. Klein, J. Parvizi, M.A. Mont, M.J. Kraay, J.M. Martell, J.L. Gilbert, C.M. Rimnac, and S.M. Kurtz -- Normal and adverse wear patterns created in-vivo on metal-on-metal surfaces : a retrieval study representing four vendors / I.C. Clarke, T.K. Donaldson, M.D. Burgett, E.J. Smith, J. Bowsher, C. Savisaar, A. John, J.Y. Lazennec, E. Mcpherson, and C.L. Peters -- Analysis of comprehensive measurements from retrieved implants to determine factors contributing to failure modes and wear / P. Campbell, E. Ebramzadeh, S. Azad, F. Billi, Z. Lu, and H. McKellop -- A protocol to assess the wear of head/neck taper junctions in large head metal-on-metal (LHMoM) hips / R.J. Underwood, S.B. Kocagoz, R. Smith, R.S. Sayles, R. Siskey, S.M. Kurtz, and P.M. Cann -- Plastic deformation from edge loading is common on retrieved metal-on-metal hips and can be predicted with finite element analysis / D. McHugh, J. Currier, F. Kennedy, J. Collier, and D. Van Citters -- Microstructure of retrievals made from standard cast HC-CoCrMo alloys / P. Stemmer, R. Pourzal, Y. Liao, L. Marks, M. Morlock, J.J. Jacobs, M.A. Wimmer, and A. Fischer -- Development of a stop-dwell-start (SDS) protocol for in vitro wear testing of metal-on-metal total hip replacements / M. Hadley, C. Hardaker, S. Williams, Z. Jin, G. Isaac, and J. Fisher -- Tribochemical reactions in metal-on-metal hip joints influence wear and corrosion / M.A. Wimmer, M.T. Mathew, M.P. Laurent, C. Nagelli, Y. Liao, L.D. Marks, R. Pourzal, A. Fischer, and J.J. Jacobs -- Denatured protein deposits identified on simulator and explant hip bearings / M. Burgett, T. Donaldson, I.C. Clarke, C. Savisaar, and J. Bowsher -- Study on tribological and electrochemical performance of metal artificial hip joint materials in simulated synovial fluids / Z.K. Hua, G. Mcknight, and J. McCloy
  • Prevalence of metal-on-metal bearings in the United States / S.M. Kurtz, K.L. Ong, E. Lau, A.S. Greenwald, and K. Bozic -- Metal-on-metal and other bearing trends among fellows of the AAOS / K.L. Urish, M. Amini, and W.M. Mihalko -- Risk of complications, revision, and cancer for metal-on-metal patients in the medicare population / K.L. Ong, E. Lau, and S.M. Kurtz -- Serum metal ion concentrations decline (but do not rapidly normalize) following revision of metal-on-metal total hip bearings / J.A. Browne, Z. Wan, W.M. Novicoff, Q. Cui, and T.E. Brown -- Low cobalt and chromium levels from a single metal-on-metal total hip arthroplasty implant / A.F. Chen, M.T. Pigott, E.J. McClain, and B.A. Klatt -- A prospective case series examining the use of a large-head metal-on-metal total hip system / V. Chatrath, I. Catelas, and P.E. Beaule -- A method to isolate and characterize wear debris from synovial fluid and tissues / A.E. Kavanaugh, P. Benya, and F. Billi -- Lymphocyte reactivity to nickel correlates with reported high-pain levels in patients with total joint arthroplasties : implications for pain-related hypersensitivity responses / M.S. Caicedo, L. Samelko, and N.J. Hallab -- Approach, rationale, and examples of metal-on-metal device retrieval and analysis for evidence-based education / J. Lemons, D. Sarver, P. Beck, D. Petersen, and A. Eberhardt -- The development of a standard method for assessing wear of explanted metal-on-metal hip joints / R.J. Underwood, M. Fowell, R. Sayles, S.M. Kurtz, and P. Cann -- Method of characterizing fretting and corrosion at the various taper connections of retrieved modular components from metal-on-metal total hip arthroplasty / G.B. Higgs, J.A. Hanzlik, D.W. MacDonald, W.M. Kane, J.S. Day, G.R. Klein, J. Parvizi, M.A. Mont, M.J. Kraay, J.M. Martell, J.L. Gilbert, C.M. Rimnac, and S.M. Kurtz -- Normal and adverse wear patterns created in-vivo on metal-on-metal surfaces : a retrieval study representing four vendors / I.C. Clarke, T.K. Donaldson, M.D. Burgett, E.J. Smith, J. Bowsher, C. Savisaar, A. John, J.Y. Lazennec, E. Mcpherson, and C.L. Peters -- Analysis of comprehensive measurements from retrieved implants to determine factors contributing to failure modes and wear / P. Campbell, E. Ebramzadeh, S. Azad, F. Billi, Z. Lu, and H. McKellop -- A protocol to assess the wear of head/neck taper junctions in large head metal-on-metal (LHMoM) hips / R.J. Underwood, S.B. Kocagoz, R. Smith, R.S. Sayles, R. Siskey, S.M. Kurtz, and P.M. Cann -- Plastic deformation from edge loading is common on retrieved metal-on-metal hips and can be predicted with finite element analysis / D. McHugh, J. Currier, F. Kennedy, J. Collier, and D. Van Citters -- Microstructure of retrievals made from standard cast HC-CoCrMo alloys / P. Stemmer, R. Pourzal, Y. Liao, L. Marks, M. Morlock, J.J. Jacobs, M.A. Wimmer, and A. Fischer -- Development of a stop-dwell-start (SDS) protocol for in vitro wear testing of metal-on-metal total hip replacements / M. Hadley, C. Hardaker, S. Williams, Z. Jin, G. Isaac, and J. Fisher -- Tribochemical reactions in metal-on-metal hip joints influence wear and corrosion / M.A. Wimmer, M.T. Mathew, M.P. Laurent, C. Nagelli, Y. Liao, L.D. Marks, R. Pourzal, A. Fischer, and J.J. Jacobs -- Denatured protein deposits identified on simulator and explant hip bearings / M. Burgett, T. Donaldson, I.C. Clarke, C. Savisaar, and J. Bowsher -- Study on tribological and electrochemical performance of metal artificial hip joint materials in simulated synovial fluids / Z.K. Hua, G. Mcknight, and J. McCloy
  • Prevalence of metal-on-metal bearings in the United States / S.M. Kurtz, K.L. Ong, E. Lau, A.S. Greenwald, and K. Bozic -- Metal-on-metal and other bearing trends among fellows of the AAOS / K.L. Urish, M. Amini, and W.M. Mihalko -- Risk of complications, revision, and cancer for metal-on-metal patients in the medicare population / K.L. Ong, E. Lau, and S.M. Kurtz -- Serum metal ion concentrations decline (but do not rapidly normalize) following revision of metal-on-metal total hip bearings / J.A. Browne, Z. Wan, W.M. Novicoff, Q. Cui, and T.E. Brown -- Low cobalt and chromium levels from a single metal-on-metal total hip arthroplasty implant / A.F. Chen, M.T. Pigott, E.J. McClain, and B.A. Klatt -- A prospective case series examining the use of a large-head metal-on-metal total hip system / V. Chatrath, I. Catelas, and P.E. Beaule -- A method to isolate and characterize wear debris from synovial fluid and tissues / A.E. Kavanaugh, P. Benya, and F. Billi -- Lymphocyte reactivity to nickel correlates with reported high-pain levels in patients with total joint arthroplasties : implications for pain-related hypersensitivity responses / M.S. Caicedo, L. Samelko, and N.J. Hallab -- Approach, rationale, and examples of metal-on-metal device retrieval and analysis for evidence-based education / J. Lemons, D. Sarver, P. Beck, D. Petersen, and A. Eberhardt -- The development of a standard method for assessing wear of explanted metal-on-metal hip joints / R.J. Underwood, M. Fowell, R. Sayles, S.M. Kurtz, and P. Cann -- Method of characterizing fretting and corrosion at the various taper connections of retrieved modular components from metal-on-metal total hip arthroplasty / G.B. Higgs, J.A. Hanzlik, D.W. MacDonald, W.M. Kane, J.S. Day, G.R. Klein, J. Parvizi, M.A. Mont, M.J. Kraay, J.M. Martell, J.L. Gilbert, C.M. Rimnac, and S.M. Kurtz -- Normal and adverse wear patterns created in-vivo on metal-on-metal surfaces : a retrieval study representing four vendors / I.C. Clarke, T.K. Donaldson, M.D. Burgett, E.J. Smith, J. Bowsher, C. Savisaar, A. John, J.Y. Lazennec, E. Mcpherson, and C.L. Peters -- Analysis of comprehensive measurements from retrieved implants to determine factors contributing to failure modes and wear / P. Campbell, E. Ebramzadeh, S. Azad, F. Billi, Z. Lu, and H. McKellop -- A protocol to assess the wear of head/neck taper junctions in large head metal-on-metal (LHMoM) hips / R.J. Underwood, S.B. Kocagoz, R. Smith, R.S. Sayles, R. Siskey, S.M. Kurtz, and P.M. Cann -- Plastic deformation from edge loading is common on retrieved metal-on-metal hips and can be predicted with finite element analysis / D. McHugh, J. Currier, F. Kennedy, J. Collier, and D. Van Citters -- Microstructure of retrievals made from standard cast HC-CoCrMo alloys / P. Stemmer, R. Pourzal, Y. Liao, L. Marks, M. Morlock, J.J. Jacobs, M.A. Wimmer, and A. Fischer -- Development of a stop-dwell-start (SDS) protocol for in vitro wear testing of metal-on-metal total hip replacements / M. Hadley, C. Hardaker, S. Williams, Z. Jin, G. Isaac, and J. Fisher -- Tribochemical reactions in metal-on-metal hip joints influence wear and corrosion / M.A. Wimmer, M.T. Mathew, M.P. Laurent, C. Nagelli, Y. Liao, L.D. Marks, R. Pourzal, A. Fischer, and J.J. Jacobs -- Denatured protein deposits identified on simulator and explant hip bearings / M. Burgett, T. Donaldson, I.C. Clarke, C. Savisaar, and J. Bowsher -- Study on tribological and electrochemical performance of metal artificial hip joint materials in simulated synovial fluids / Z.K. Hua, G. Mcknight, and J. McCloy
  • Prevalence of metal-on-metal bearings in the United States / S.M. Kurtz, K.L. Ong, E. Lau, A.S. Greenwald, and K. Bozic -- Metal-on-metal and other bearing trends among fellows of the AAOS / K.L. Urish, M. Amini, and W.M. Mihalko -- Risk of complications, revision, and cancer for metal-on-metal patients in the medicare population / K.L. Ong, E. Lau, and S.M. Kurtz -- Serum metal ion concentrations decline (but do not rapidly normalize) following revision of metal-on-metal total hip bearings / J.A. Browne, Z. Wan, W.M. Novicoff, Q. Cui, and T.E. Brown -- Low cobalt and chromium levels from a single metal-on-metal total hip arthroplasty implant / A.F. Chen, M.T. Pigott, E.J. McClain, and B.A. Klatt -- A prospective case series examining the use of a large-head metal-on-metal total hip system / V. Chatrath, I. Catelas, and P.E. Beaule -- A method to isolate and characterize wear debris from synovial fluid and tissues / A.E. Kavanaugh, P. Benya, and F. Billi -- Lymphocyte reactivity to nickel correlates with reported high-pain levels in patients with total joint arthroplasties : implications for pain-related hypersensitivity responses / M.S. Caicedo, L. Samelko, and N.J. Hallab -- Approach, rationale, and examples of metal-on-metal device retrieval and analysis for evidence-based education / J. Lemons, D. Sarver, P. Beck, D. Petersen, and A. Eberhardt -- The development of a standard method for assessing wear of explanted metal-on-metal hip joints / R.J. Underwood, M. Fowell, R. Sayles, S.M. Kurtz, and P. Cann -- Method of characterizing fretting and corrosion at the various taper connections of retrieved modular components from metal-on-metal total hip arthroplasty / G.B. Higgs, J.A. Hanzlik, D.W. MacDonald, W.M. Kane, J.S. Day, G.R. Klein, J. Parvizi, M.A. Mont, M.J. Kraay, J.M. Martell, J.L. Gilbert, C.M. Rimnac, and S.M. Kurtz -- Normal and adverse wear patterns created in-vivo on metal-on-metal surfaces : a retrieval study representing four vendors / I.C. Clarke, T.K. Donaldson, M.D. Burgett, E.J. Smith, J. Bowsher, C. Savisaar, A. John, J.Y. Lazennec, E. Mcpherson, and C.L. Peters -- Analysis of comprehensive measurements from retrieved implants to determine factors contributing to failure modes and wear / P. Campbell, E. Ebramzadeh, S. Azad, F. Billi, Z. Lu, and H. McKellop -- A protocol to assess the wear of head/neck taper junctions in large head metal-on-metal (LHMoM) hips / R.J. Underwood, S.B. Kocagoz, R. Smith, R.S. Sayles, R. Siskey, S.M. Kurtz, and P.M. Cann -- Plastic deformation from edge loading is common on retrieved metal-on-metal hips and can be predicted with finite element analysis / D. McHugh, J. Currier, F. Kennedy, J. Collier, and D. Van Citters -- Microstructure of retrievals made from standard cast HC-CoCrMo alloys / P. Stemmer, R. Pourzal, Y. Liao, L. Marks, M. Morlock, J.J. Jacobs, M.A. Wimmer, and A. Fischer -- Development of a stop-dwell-start (SDS) protocol for in vitro wear testing of metal-on-metal total hip replacements / M. Hadley, C. Hardaker, S. Williams, Z. Jin, G. Isaac, and J. Fisher -- Tribochemical reactions in metal-on-metal hip joints influence wear and corrosion / M.A. Wimmer, M.T. Mathew, M.P. Laurent, C. Nagelli, Y. Liao, L.D. Marks, R. Pourzal, A. Fischer, and J.J. Jacobs -- Denatured protein deposits identified on simulator and explant hip bearings / M. Burgett, T. Donaldson, I.C. Clarke, C. Savisaar, and J. Bowsher -- Study on tribological and electrochemical performance of metal artificial hip joint materials in simulated synovial fluids / Z.K. Hua, G. Mcknight, and J. McCloy
  • Prevalence of metal-on-metal bearings in the United States / S.M. Kurtz, K.L. Ong, E. Lau, A.S. Greenwald, and K. Bozic -- Metal-on-metal and other bearing trends among fellows of the AAOS / K.L. Urish, M. Amini, and W.M. Mihalko -- Risk of complications, revision, and cancer for metal-on-metal patients in the medicare population / K.L. Ong, E. Lau, and S.M. Kurtz -- Serum metal ion concentrations decline (but do not rapidly normalize) following revision of metal-on-metal total hip bearings / J.A. Browne, Z. Wan, W.M. Novicoff, Q. Cui, and T.E. Brown -- Low cobalt and chromium levels from a single metal-on-metal total hip arthroplasty implant / A.F. Chen, M.T. Pigott, E.J. McClain, and B.A. Klatt -- A prospective case series examining the use of a large-head metal-on-metal total hip system / V. Chatrath, I. Catelas, and P.E. Beaule -- A method to isolate and characterize wear debris from synovial fluid and tissues / A.E. Kavanaugh, P. Benya, and F. Billi -- Lymphocyte reactivity to nickel correlates with reported high-pain levels in patients with total joint arthroplasties : implications for pain-related hypersensitivity responses / M.S. Caicedo, L. Samelko, and N.J. Hallab -- Approach, rationale, and examples of metal-on-metal device retrieval and analysis for evidence-based education / J. Lemons, D. Sarver, P. Beck, D. Petersen, and A. Eberhardt -- The development of a standard method for assessing wear of explanted metal-on-metal hip joints / R.J. Underwood, M. Fowell, R. Sayles, S.M. Kurtz, and P. Cann -- Method of characterizing fretting and corrosion at the various taper connections of retrieved modular components from metal-on-metal total hip arthroplasty / G.B. Higgs, J.A. Hanzlik, D.W. MacDonald, W.M. Kane, J.S. Day, G.R. Klein, J. Parvizi, M.A. Mont, M.J. Kraay, J.M. Martell, J.L. Gilbert, C.M. Rimnac, and S.M. Kurtz -- Normal and adverse wear patterns created in-vivo on metal-on-metal surfaces : a retrieval study representing four vendors / I.C. Clarke, T.K. Donaldson, M.D. Burgett, E.J. Smith, J. Bowsher, C. Savisaar, A. John, J.Y. Lazennec, E. Mcpherson, and C.L. Peters -- Analysis of comprehensive measurements from retrieved implants to determine factors contributing to failure modes and wear / P. Campbell, E. Ebramzadeh, S. Azad, F. Billi, Z. Lu, and H. McKellop -- A protocol to assess the wear of head/neck taper junctions in large head metal-on-metal (LHMoM) hips / R.J. Underwood, S.B. Kocagoz, R. Smith, R.S. Sayles, R. Siskey, S.M. Kurtz, and P.M. Cann -- Plastic deformation from edge loading is common on retrieved metal-on-metal hips and can be predicted with finite element analysis / D. McHugh, J. Currier, F. Kennedy, J. Collier, and D. Van Citters -- Microstructure of retrievals made from standard cast HC-CoCrMo alloys / P. Stemmer, R. Pourzal, Y. Liao, L. Marks, M. Morlock, J.J. Jacobs, M.A. Wimmer, and A. Fischer -- Development of a stop-dwell-start (SDS) protocol for in vitro wear testing of metal-on-metal total hip replacements / M. Hadley, C. Hardaker, S. Williams, Z. Jin, G. Isaac, and J. Fisher -- Tribochemical reactions in metal-on-metal hip joints influence wear and corrosion / M.A. Wimmer, M.T. Mathew, M.P. Laurent, C. Nagelli, Y. Liao, L.D. Marks, R. Pourzal, A. Fischer, and J.J. Jacobs -- Denatured protein deposits identified on simulator and explant hip bearings / M. Burgett, T. Donaldson, I.C. Clarke, C. Savisaar, and J. Bowsher -- Study on tribological and electrochemical performance of metal artificial hip joint materials in simulated synovial fluids / Z.K. Hua, G. Mcknight, and J. McCloy
Control code
OCM1bookssj0001184290
Dimensions
unknown
Isbn
9780803175464
Isbn Type
(alk. paper)
Lccn
2013023318
Specific material designation
remote
System control number
(WaSeSS)bookssj0001184290

Library Locations

    • Curtis Laws Wilson LibraryBorrow it
      400 West 14th Street, Rolla, MO, 65409, US
      37.955220 -91.772210
Processing Feedback ...