Coverart for item
The Resource Mobile bearing total knee replacement devices, JAI guest editors, Kathy K. Trier, A. Seth Greenwald, (electronic resource)

Mobile bearing total knee replacement devices, JAI guest editors, Kathy K. Trier, A. Seth Greenwald, (electronic resource)

Label
Mobile bearing total knee replacement devices
Title
Mobile bearing total knee replacement devices
Statement of responsibility
JAI guest editors, Kathy K. Trier, A. Seth Greenwald
Contributor
Subject
Language
eng
Member of
Cataloging source
DNLM
NLM call number
  • 2013 D-458
  • WE 870
http://library.link/vocab/relatedWorkOrContributorName
  • Trier, Kathy K
  • Greenwald, A. Seth
  • ASTM International
Series statement
Journal of ASTM International. Selected technical papers
Series volume
STP1531
http://library.link/vocab/subjectName
  • Knee Prosthesis
  • Arthroplasty, Replacement, Knee
  • Equipment Failure Analysis
  • Prosthesis Failure
  • Treatment Outcome
Label
Mobile bearing total knee replacement devices, JAI guest editors, Kathy K. Trier, A. Seth Greenwald, (electronic resource)
Instantiates
Publication
Bibliography note
Includes bibliographical references and indexes
Contents
  • Standard testing methods for mobile bearing knees / P.S. Walker and H. Haider -- Comparison of mobile bearing and fixed bearing total knee arthroplasty outcomes : a review of the literature / J. Sykes ... [et al.] -- Year evolution of the rotating-platform total knee replacement : coping with "spinout" and wear / F.F. Buechel ... [et al.] -- The incidence of anterior knee pain and crepitation after total knee replacement : a matched pair analysis between rotating platform and fixed bearing posterior stabilized designs / A.S. Ranawat ... [et al.] -- Early instability with mobile bearing total knee arthroplasty : a series of twenty-five cases / J.T. Moskal, S.R. Ridgeway, and V.J. Williams -- Utilizing validated computational models to predict tibial insert abrasion in mobile bearing knees : a design performance standard / E. Morra and A.S. Greenwald -- Mobility and contact mechanics of a rotating platform total knee replacement / J.K. Otto, J.J. Callaghan, and T.D. Brown -- Systematic review of complications in TKA mobile bearing knees / C. Hopley and L. Crossett -- The contribution of mobile bearing knee design in optimizing tibial rotation in total knee arthroplasty / J.B. Stiehl -- In-vitro wear and radiographic analyses of high flexion posterior stabilized mobile- and fixed-bearing knee implants / O. Popoola, N. Yu, and G. Scuderi -- Clinical results of a total knee prosthesis with floating platform at 5.5 years / R. Miehlke ... [et al.] -- Damage and wear : an important distinction in rotating platform knee bearings -- J.H. Currier ... [et al.] -- Wear rate in a series of retrieved RP knee bearings -- J.H. Currier ... [et al.] -- Wear of a mobile bearing uni-compartmental knee replacement prosthesis : a comparison of in vitro and in vivo wear rates -- P.J. Ellison ... [et al.] -- Wear advantage of a rotating bearing knee-an in vitro study / D. Angibaud ... [et al.] -- In vitro knee wear, kinematics, and particle morphology among different bearing geometries in a mobile bearing knee system / T.M. Grupp ... [et al.] -- Wear of mobile bearing knees : is it necessarily less? -- H. Haider and C. Kaddick
  • Standard testing methods for mobile bearing knees / P.S. Walker and H. Haider -- Comparison of mobile bearing and fixed bearing total knee arthroplasty outcomes : a review of the literature / J. Sykes ... [et al.] -- Year evolution of the rotating-platform total knee replacement : coping with "spinout" and wear / F.F. Buechel ... [et al.] -- The incidence of anterior knee pain and crepitation after total knee replacement : a matched pair analysis between rotating platform and fixed bearing posterior stabilized designs / A.S. Ranawat ... [et al.] -- Early instability with mobile bearing total knee arthroplasty : a series of twenty-five cases / J.T. Moskal, S.R. Ridgeway, and V.J. Williams -- Utilizing validated computational models to predict tibial insert abrasion in mobile bearing knees : a design performance standard / E. Morra and A.S. Greenwald -- Mobility and contact mechanics of a rotating platform total knee replacement / J.K. Otto, J.J. Callaghan, and T.D. Brown -- Systematic review of complications in TKA mobile bearing knees / C. Hopley and L. Crossett -- The contribution of mobile bearing knee design in optimizing tibial rotation in total knee arthroplasty / J.B. Stiehl -- In-vitro wear and radiographic analyses of high flexion posterior stabilized mobile- and fixed-bearing knee implants / O. Popoola, N. Yu, and G. Scuderi -- Clinical results of a total knee prosthesis with floating platform at 5.5 years / R. Miehlke ... [et al.] -- Damage and wear : an important distinction in rotating platform knee bearings -- J.H. Currier ... [et al.] -- Wear rate in a series of retrieved RP knee bearings -- J.H. Currier ... [et al.] -- Wear of a mobile bearing uni-compartmental knee replacement prosthesis : a comparison of in vitro and in vivo wear rates -- P.J. Ellison ... [et al.] -- Wear advantage of a rotating bearing knee-an in vitro study / D. Angibaud ... [et al.] -- In vitro knee wear, kinematics, and particle morphology among different bearing geometries in a mobile bearing knee system / T.M. Grupp ... [et al.] -- Wear of mobile bearing knees : is it necessarily less? -- H. Haider and C. Kaddick
  • Standard testing methods for mobile bearing knees / P.S. Walker and H. Haider -- Comparison of mobile bearing and fixed bearing total knee arthroplasty outcomes : a review of the literature / J. Sykes ... [et al.] -- Year evolution of the rotating-platform total knee replacement : coping with "spinout" and wear / F.F. Buechel ... [et al.] -- The incidence of anterior knee pain and crepitation after total knee replacement : a matched pair analysis between rotating platform and fixed bearing posterior stabilized designs / A.S. Ranawat ... [et al.] -- Early instability with mobile bearing total knee arthroplasty : a series of twenty-five cases / J.T. Moskal, S.R. Ridgeway, and V.J. Williams -- Utilizing validated computational models to predict tibial insert abrasion in mobile bearing knees : a design performance standard / E. Morra and A.S. Greenwald -- Mobility and contact mechanics of a rotating platform total knee replacement / J.K. Otto, J.J. Callaghan, and T.D. Brown -- Systematic review of complications in TKA mobile bearing knees / C. Hopley and L. Crossett -- The contribution of mobile bearing knee design in optimizing tibial rotation in total knee arthroplasty / J.B. Stiehl -- In-vitro wear and radiographic analyses of high flexion posterior stabilized mobile- and fixed-bearing knee implants / O. Popoola, N. Yu, and G. Scuderi -- Clinical results of a total knee prosthesis with floating platform at 5.5 years / R. Miehlke ... [et al.] -- Damage and wear : an important distinction in rotating platform knee bearings -- J.H. Currier ... [et al.] -- Wear rate in a series of retrieved RP knee bearings -- J.H. Currier ... [et al.] -- Wear of a mobile bearing uni-compartmental knee replacement prosthesis : a comparison of in vitro and in vivo wear rates -- P.J. Ellison ... [et al.] -- Wear advantage of a rotating bearing knee-an in vitro study / D. Angibaud ... [et al.] -- In vitro knee wear, kinematics, and particle morphology among different bearing geometries in a mobile bearing knee system / T.M. Grupp ... [et al.] -- Wear of mobile bearing knees : is it necessarily less? -- H. Haider and C. Kaddick
  • Standard testing methods for mobile bearing knees / P.S. Walker and H. Haider -- Comparison of mobile bearing and fixed bearing total knee arthroplasty outcomes : a review of the literature / J. Sykes ... [et al.] -- Year evolution of the rotating-platform total knee replacement : coping with "spinout" and wear / F.F. Buechel ... [et al.] -- The incidence of anterior knee pain and crepitation after total knee replacement : a matched pair analysis between rotating platform and fixed bearing posterior stabilized designs / A.S. Ranawat ... [et al.] -- Early instability with mobile bearing total knee arthroplasty : a series of twenty-five cases / J.T. Moskal, S.R. Ridgeway, and V.J. Williams -- Utilizing validated computational models to predict tibial insert abrasion in mobile bearing knees : a design performance standard / E. Morra and A.S. Greenwald -- Mobility and contact mechanics of a rotating platform total knee replacement / J.K. Otto, J.J. Callaghan, and T.D. Brown -- Systematic review of complications in TKA mobile bearing knees / C. Hopley and L. Crossett -- The contribution of mobile bearing knee design in optimizing tibial rotation in total knee arthroplasty / J.B. Stiehl -- In-vitro wear and radiographic analyses of high flexion posterior stabilized mobile- and fixed-bearing knee implants / O. Popoola, N. Yu, and G. Scuderi -- Clinical results of a total knee prosthesis with floating platform at 5.5 years / R. Miehlke ... [et al.] -- Damage and wear : an important distinction in rotating platform knee bearings -- J.H. Currier ... [et al.] -- Wear rate in a series of retrieved RP knee bearings -- J.H. Currier ... [et al.] -- Wear of a mobile bearing uni-compartmental knee replacement prosthesis : a comparison of in vitro and in vivo wear rates -- P.J. Ellison ... [et al.] -- Wear advantage of a rotating bearing knee-an in vitro study / D. Angibaud ... [et al.] -- In vitro knee wear, kinematics, and particle morphology among different bearing geometries in a mobile bearing knee system / T.M. Grupp ... [et al.] -- Wear of mobile bearing knees : is it necessarily less? -- H. Haider and C. Kaddick
  • Standard testing methods for mobile bearing knees / P.S. Walker and H. Haider -- Comparison of mobile bearing and fixed bearing total knee arthroplasty outcomes : a review of the literature / J. Sykes ... [et al.] -- Year evolution of the rotating-platform total knee replacement : coping with "spinout" and wear / F.F. Buechel ... [et al.] -- The incidence of anterior knee pain and crepitation after total knee replacement : a matched pair analysis between rotating platform and fixed bearing posterior stabilized designs / A.S. Ranawat ... [et al.] -- Early instability with mobile bearing total knee arthroplasty : a series of twenty-five cases / J.T. Moskal, S.R. Ridgeway, and V.J. Williams -- Utilizing validated computational models to predict tibial insert abrasion in mobile bearing knees : a design performance standard / E. Morra and A.S. Greenwald -- Mobility and contact mechanics of a rotating platform total knee replacement / J.K. Otto, J.J. Callaghan, and T.D. Brown -- Systematic review of complications in TKA mobile bearing knees / C. Hopley and L. Crossett -- The contribution of mobile bearing knee design in optimizing tibial rotation in total knee arthroplasty / J.B. Stiehl -- In-vitro wear and radiographic analyses of high flexion posterior stabilized mobile- and fixed-bearing knee implants / O. Popoola, N. Yu, and G. Scuderi -- Clinical results of a total knee prosthesis with floating platform at 5.5 years / R. Miehlke ... [et al.] -- Damage and wear : an important distinction in rotating platform knee bearings -- J.H. Currier ... [et al.] -- Wear rate in a series of retrieved RP knee bearings -- J.H. Currier ... [et al.] -- Wear of a mobile bearing uni-compartmental knee replacement prosthesis : a comparison of in vitro and in vivo wear rates -- P.J. Ellison ... [et al.] -- Wear advantage of a rotating bearing knee-an in vitro study / D. Angibaud ... [et al.] -- In vitro knee wear, kinematics, and particle morphology among different bearing geometries in a mobile bearing knee system / T.M. Grupp ... [et al.] -- Wear of mobile bearing knees : is it necessarily less? -- H. Haider and C. Kaddick
  • Standard testing methods for mobile bearing knees / P.S. Walker and H. Haider -- Comparison of mobile bearing and fixed bearing total knee arthroplasty outcomes : a review of the literature / J. Sykes ... [et al.] -- Year evolution of the rotating-platform total knee replacement : coping with "spinout" and wear / F.F. Buechel ... [et al.] -- The incidence of anterior knee pain and crepitation after total knee replacement : a matched pair analysis between rotating platform and fixed bearing posterior stabilized designs / A.S. Ranawat ... [et al.] -- Early instability with mobile bearing total knee arthroplasty : a series of twenty-five cases / J.T. Moskal, S.R. Ridgeway, and V.J. Williams -- Utilizing validated computational models to predict tibial insert abrasion in mobile bearing knees : a design performance standard / E. Morra and A.S. Greenwald -- Mobility and contact mechanics of a rotating platform total knee replacement / J.K. Otto, J.J. Callaghan, and T.D. Brown -- Systematic review of complications in TKA mobile bearing knees / C. Hopley and L. Crossett -- The contribution of mobile bearing knee design in optimizing tibial rotation in total knee arthroplasty / J.B. Stiehl -- In-vitro wear and radiographic analyses of high flexion posterior stabilized mobile- and fixed-bearing knee implants / O. Popoola, N. Yu, and G. Scuderi -- Clinical results of a total knee prosthesis with floating platform at 5.5 years / R. Miehlke ... [et al.] -- Damage and wear : an important distinction in rotating platform knee bearings -- J.H. Currier ... [et al.] -- Wear rate in a series of retrieved RP knee bearings -- J.H. Currier ... [et al.] -- Wear of a mobile bearing uni-compartmental knee replacement prosthesis : a comparison of in vitro and in vivo wear rates -- P.J. Ellison ... [et al.] -- Wear advantage of a rotating bearing knee-an in vitro study / D. Angibaud ... [et al.] -- In vitro knee wear, kinematics, and particle morphology among different bearing geometries in a mobile bearing knee system / T.M. Grupp ... [et al.] -- Wear of mobile bearing knees : is it necessarily less? -- H. Haider and C. Kaddick
Control code
OCM1bookssj0001184297
Dimensions
unknown
Isbn
9780803175174
Lccn
2012006149
Specific material designation
remote
System control number
(WaSeSS)bookssj0001184297
Label
Mobile bearing total knee replacement devices, JAI guest editors, Kathy K. Trier, A. Seth Greenwald, (electronic resource)
Publication
Bibliography note
Includes bibliographical references and indexes
Contents
  • Standard testing methods for mobile bearing knees / P.S. Walker and H. Haider -- Comparison of mobile bearing and fixed bearing total knee arthroplasty outcomes : a review of the literature / J. Sykes ... [et al.] -- Year evolution of the rotating-platform total knee replacement : coping with "spinout" and wear / F.F. Buechel ... [et al.] -- The incidence of anterior knee pain and crepitation after total knee replacement : a matched pair analysis between rotating platform and fixed bearing posterior stabilized designs / A.S. Ranawat ... [et al.] -- Early instability with mobile bearing total knee arthroplasty : a series of twenty-five cases / J.T. Moskal, S.R. Ridgeway, and V.J. Williams -- Utilizing validated computational models to predict tibial insert abrasion in mobile bearing knees : a design performance standard / E. Morra and A.S. Greenwald -- Mobility and contact mechanics of a rotating platform total knee replacement / J.K. Otto, J.J. Callaghan, and T.D. Brown -- Systematic review of complications in TKA mobile bearing knees / C. Hopley and L. Crossett -- The contribution of mobile bearing knee design in optimizing tibial rotation in total knee arthroplasty / J.B. Stiehl -- In-vitro wear and radiographic analyses of high flexion posterior stabilized mobile- and fixed-bearing knee implants / O. Popoola, N. Yu, and G. Scuderi -- Clinical results of a total knee prosthesis with floating platform at 5.5 years / R. Miehlke ... [et al.] -- Damage and wear : an important distinction in rotating platform knee bearings -- J.H. Currier ... [et al.] -- Wear rate in a series of retrieved RP knee bearings -- J.H. Currier ... [et al.] -- Wear of a mobile bearing uni-compartmental knee replacement prosthesis : a comparison of in vitro and in vivo wear rates -- P.J. Ellison ... [et al.] -- Wear advantage of a rotating bearing knee-an in vitro study / D. Angibaud ... [et al.] -- In vitro knee wear, kinematics, and particle morphology among different bearing geometries in a mobile bearing knee system / T.M. Grupp ... [et al.] -- Wear of mobile bearing knees : is it necessarily less? -- H. Haider and C. Kaddick
  • Standard testing methods for mobile bearing knees / P.S. Walker and H. Haider -- Comparison of mobile bearing and fixed bearing total knee arthroplasty outcomes : a review of the literature / J. Sykes ... [et al.] -- Year evolution of the rotating-platform total knee replacement : coping with "spinout" and wear / F.F. Buechel ... [et al.] -- The incidence of anterior knee pain and crepitation after total knee replacement : a matched pair analysis between rotating platform and fixed bearing posterior stabilized designs / A.S. Ranawat ... [et al.] -- Early instability with mobile bearing total knee arthroplasty : a series of twenty-five cases / J.T. Moskal, S.R. Ridgeway, and V.J. Williams -- Utilizing validated computational models to predict tibial insert abrasion in mobile bearing knees : a design performance standard / E. Morra and A.S. Greenwald -- Mobility and contact mechanics of a rotating platform total knee replacement / J.K. Otto, J.J. Callaghan, and T.D. Brown -- Systematic review of complications in TKA mobile bearing knees / C. Hopley and L. Crossett -- The contribution of mobile bearing knee design in optimizing tibial rotation in total knee arthroplasty / J.B. Stiehl -- In-vitro wear and radiographic analyses of high flexion posterior stabilized mobile- and fixed-bearing knee implants / O. Popoola, N. Yu, and G. Scuderi -- Clinical results of a total knee prosthesis with floating platform at 5.5 years / R. Miehlke ... [et al.] -- Damage and wear : an important distinction in rotating platform knee bearings -- J.H. Currier ... [et al.] -- Wear rate in a series of retrieved RP knee bearings -- J.H. Currier ... [et al.] -- Wear of a mobile bearing uni-compartmental knee replacement prosthesis : a comparison of in vitro and in vivo wear rates -- P.J. Ellison ... [et al.] -- Wear advantage of a rotating bearing knee-an in vitro study / D. Angibaud ... [et al.] -- In vitro knee wear, kinematics, and particle morphology among different bearing geometries in a mobile bearing knee system / T.M. Grupp ... [et al.] -- Wear of mobile bearing knees : is it necessarily less? -- H. Haider and C. Kaddick
  • Standard testing methods for mobile bearing knees / P.S. Walker and H. Haider -- Comparison of mobile bearing and fixed bearing total knee arthroplasty outcomes : a review of the literature / J. Sykes ... [et al.] -- Year evolution of the rotating-platform total knee replacement : coping with "spinout" and wear / F.F. Buechel ... [et al.] -- The incidence of anterior knee pain and crepitation after total knee replacement : a matched pair analysis between rotating platform and fixed bearing posterior stabilized designs / A.S. Ranawat ... [et al.] -- Early instability with mobile bearing total knee arthroplasty : a series of twenty-five cases / J.T. Moskal, S.R. Ridgeway, and V.J. Williams -- Utilizing validated computational models to predict tibial insert abrasion in mobile bearing knees : a design performance standard / E. Morra and A.S. Greenwald -- Mobility and contact mechanics of a rotating platform total knee replacement / J.K. Otto, J.J. Callaghan, and T.D. Brown -- Systematic review of complications in TKA mobile bearing knees / C. Hopley and L. Crossett -- The contribution of mobile bearing knee design in optimizing tibial rotation in total knee arthroplasty / J.B. Stiehl -- In-vitro wear and radiographic analyses of high flexion posterior stabilized mobile- and fixed-bearing knee implants / O. Popoola, N. Yu, and G. Scuderi -- Clinical results of a total knee prosthesis with floating platform at 5.5 years / R. Miehlke ... [et al.] -- Damage and wear : an important distinction in rotating platform knee bearings -- J.H. Currier ... [et al.] -- Wear rate in a series of retrieved RP knee bearings -- J.H. Currier ... [et al.] -- Wear of a mobile bearing uni-compartmental knee replacement prosthesis : a comparison of in vitro and in vivo wear rates -- P.J. Ellison ... [et al.] -- Wear advantage of a rotating bearing knee-an in vitro study / D. Angibaud ... [et al.] -- In vitro knee wear, kinematics, and particle morphology among different bearing geometries in a mobile bearing knee system / T.M. Grupp ... [et al.] -- Wear of mobile bearing knees : is it necessarily less? -- H. Haider and C. Kaddick
  • Standard testing methods for mobile bearing knees / P.S. Walker and H. Haider -- Comparison of mobile bearing and fixed bearing total knee arthroplasty outcomes : a review of the literature / J. Sykes ... [et al.] -- Year evolution of the rotating-platform total knee replacement : coping with "spinout" and wear / F.F. Buechel ... [et al.] -- The incidence of anterior knee pain and crepitation after total knee replacement : a matched pair analysis between rotating platform and fixed bearing posterior stabilized designs / A.S. Ranawat ... [et al.] -- Early instability with mobile bearing total knee arthroplasty : a series of twenty-five cases / J.T. Moskal, S.R. Ridgeway, and V.J. Williams -- Utilizing validated computational models to predict tibial insert abrasion in mobile bearing knees : a design performance standard / E. Morra and A.S. Greenwald -- Mobility and contact mechanics of a rotating platform total knee replacement / J.K. Otto, J.J. Callaghan, and T.D. Brown -- Systematic review of complications in TKA mobile bearing knees / C. Hopley and L. Crossett -- The contribution of mobile bearing knee design in optimizing tibial rotation in total knee arthroplasty / J.B. Stiehl -- In-vitro wear and radiographic analyses of high flexion posterior stabilized mobile- and fixed-bearing knee implants / O. Popoola, N. Yu, and G. Scuderi -- Clinical results of a total knee prosthesis with floating platform at 5.5 years / R. Miehlke ... [et al.] -- Damage and wear : an important distinction in rotating platform knee bearings -- J.H. Currier ... [et al.] -- Wear rate in a series of retrieved RP knee bearings -- J.H. Currier ... [et al.] -- Wear of a mobile bearing uni-compartmental knee replacement prosthesis : a comparison of in vitro and in vivo wear rates -- P.J. Ellison ... [et al.] -- Wear advantage of a rotating bearing knee-an in vitro study / D. Angibaud ... [et al.] -- In vitro knee wear, kinematics, and particle morphology among different bearing geometries in a mobile bearing knee system / T.M. Grupp ... [et al.] -- Wear of mobile bearing knees : is it necessarily less? -- H. Haider and C. Kaddick
  • Standard testing methods for mobile bearing knees / P.S. Walker and H. Haider -- Comparison of mobile bearing and fixed bearing total knee arthroplasty outcomes : a review of the literature / J. Sykes ... [et al.] -- Year evolution of the rotating-platform total knee replacement : coping with "spinout" and wear / F.F. Buechel ... [et al.] -- The incidence of anterior knee pain and crepitation after total knee replacement : a matched pair analysis between rotating platform and fixed bearing posterior stabilized designs / A.S. Ranawat ... [et al.] -- Early instability with mobile bearing total knee arthroplasty : a series of twenty-five cases / J.T. Moskal, S.R. Ridgeway, and V.J. Williams -- Utilizing validated computational models to predict tibial insert abrasion in mobile bearing knees : a design performance standard / E. Morra and A.S. Greenwald -- Mobility and contact mechanics of a rotating platform total knee replacement / J.K. Otto, J.J. Callaghan, and T.D. Brown -- Systematic review of complications in TKA mobile bearing knees / C. Hopley and L. Crossett -- The contribution of mobile bearing knee design in optimizing tibial rotation in total knee arthroplasty / J.B. Stiehl -- In-vitro wear and radiographic analyses of high flexion posterior stabilized mobile- and fixed-bearing knee implants / O. Popoola, N. Yu, and G. Scuderi -- Clinical results of a total knee prosthesis with floating platform at 5.5 years / R. Miehlke ... [et al.] -- Damage and wear : an important distinction in rotating platform knee bearings -- J.H. Currier ... [et al.] -- Wear rate in a series of retrieved RP knee bearings -- J.H. Currier ... [et al.] -- Wear of a mobile bearing uni-compartmental knee replacement prosthesis : a comparison of in vitro and in vivo wear rates -- P.J. Ellison ... [et al.] -- Wear advantage of a rotating bearing knee-an in vitro study / D. Angibaud ... [et al.] -- In vitro knee wear, kinematics, and particle morphology among different bearing geometries in a mobile bearing knee system / T.M. Grupp ... [et al.] -- Wear of mobile bearing knees : is it necessarily less? -- H. Haider and C. Kaddick
  • Standard testing methods for mobile bearing knees / P.S. Walker and H. Haider -- Comparison of mobile bearing and fixed bearing total knee arthroplasty outcomes : a review of the literature / J. Sykes ... [et al.] -- Year evolution of the rotating-platform total knee replacement : coping with "spinout" and wear / F.F. Buechel ... [et al.] -- The incidence of anterior knee pain and crepitation after total knee replacement : a matched pair analysis between rotating platform and fixed bearing posterior stabilized designs / A.S. Ranawat ... [et al.] -- Early instability with mobile bearing total knee arthroplasty : a series of twenty-five cases / J.T. Moskal, S.R. Ridgeway, and V.J. Williams -- Utilizing validated computational models to predict tibial insert abrasion in mobile bearing knees : a design performance standard / E. Morra and A.S. Greenwald -- Mobility and contact mechanics of a rotating platform total knee replacement / J.K. Otto, J.J. Callaghan, and T.D. Brown -- Systematic review of complications in TKA mobile bearing knees / C. Hopley and L. Crossett -- The contribution of mobile bearing knee design in optimizing tibial rotation in total knee arthroplasty / J.B. Stiehl -- In-vitro wear and radiographic analyses of high flexion posterior stabilized mobile- and fixed-bearing knee implants / O. Popoola, N. Yu, and G. Scuderi -- Clinical results of a total knee prosthesis with floating platform at 5.5 years / R. Miehlke ... [et al.] -- Damage and wear : an important distinction in rotating platform knee bearings -- J.H. Currier ... [et al.] -- Wear rate in a series of retrieved RP knee bearings -- J.H. Currier ... [et al.] -- Wear of a mobile bearing uni-compartmental knee replacement prosthesis : a comparison of in vitro and in vivo wear rates -- P.J. Ellison ... [et al.] -- Wear advantage of a rotating bearing knee-an in vitro study / D. Angibaud ... [et al.] -- In vitro knee wear, kinematics, and particle morphology among different bearing geometries in a mobile bearing knee system / T.M. Grupp ... [et al.] -- Wear of mobile bearing knees : is it necessarily less? -- H. Haider and C. Kaddick
Control code
OCM1bookssj0001184297
Dimensions
unknown
Isbn
9780803175174
Lccn
2012006149
Specific material designation
remote
System control number
(WaSeSS)bookssj0001184297

Library Locations

    • Curtis Laws Wilson LibraryBorrow it
      400 West 14th Street, Rolla, MO, 65409, US
      37.955220 -91.772210
Processing Feedback ...