Integrated design methodology for isolated floor systems in single-degree-of-freedom structural fuse systems
Resource Information
The work Integrated design methodology for isolated floor systems in single-degree-of-freedom structural fuse systems represents a distinct intellectual or artistic creation found in Missouri University of Science & Technology Library. This resource is a combination of several types including: Work, Language Material, Books.
The Resource
Integrated design methodology for isolated floor systems in single-degree-of-freedom structural fuse systems
Resource Information
The work Integrated design methodology for isolated floor systems in single-degree-of-freedom structural fuse systems represents a distinct intellectual or artistic creation found in Missouri University of Science & Technology Library. This resource is a combination of several types including: Work, Language Material, Books.
- Label
- Integrated design methodology for isolated floor systems in single-degree-of-freedom structural fuse systems
- Statement of responsibility
- by Shenlei Cui, Michel Bruneau and Michael C. Constantinou
- Language
- eng
- Summary
- "This study investigates methods to reduce floor acceleration demands in buildings with structural fuses. A strategy is proposed that combines passive hysteretic energy dissipation devices (PED) with isolated floors in rooms where acceleration-sensitive equipment is located. Two kinds of isolated floor systems were studied. The first isolated floor systems used concrete ball-in-cone (BNC) isolators with rubber and polyurethane spherical solid balls, instead of steel balls, as the rolling balls between the top and bottom concrete bearing plates. A multi-directional spring unit was used as the isolator in second isolated floor system. Characterization tests were conducted on these two isolated floor systems, from single isolator to complete system; and models of single-degree-of-freedom (SDOF) structural fuse frames with these two isolated floor systems were developed. Studies were then conducted to determine the preferred parameter values to be used in design, and to establish how the combined systems behave under different mass ratios of the isolated floor system to the base SDOF structural fuse structure. Finally, combined design concepts considering both the design of the base SDOF structural fuse structure and the design of the isolated floor system on top were developed for each kind of isolated floor system"--Page iii
- Cataloging source
- UMR
- Funding information
- Supported primarily by the Earthquake Engineering Research Centers Program of the National Science Foundation
- Illustrations
- illustrations
- Index
- no index present
- LC call number
- TA658.44
- LC item number
- .C85 2012
- Literary form
- non fiction
- Nature of contents
-
- dictionaries
- bibliography
- technical reports
- Series statement
- Technical report MCEER,
- Series volume
- 12-0004
Context
Context of Integrated design methodology for isolated floor systems in single-degree-of-freedom structural fuse systemsWork of
No resources found
No enriched resources found
Embed
Settings
Select options that apply then copy and paste the RDF/HTML data fragment to include in your application
Embed this data in a secure (HTTPS) page:
Layout options:
Include data citation:
<div class="citation" vocab="http://schema.org/"><i class="fa fa-external-link-square fa-fw"></i> Data from <span resource="http://link.library.mst.edu/resource/KHdPY8GDlOI/" typeof="CreativeWork http://bibfra.me/vocab/lite/Work"><span property="name http://bibfra.me/vocab/lite/label"><a href="http://link.library.mst.edu/resource/KHdPY8GDlOI/">Integrated design methodology for isolated floor systems in single-degree-of-freedom structural fuse systems</a></span> - <span property="potentialAction" typeOf="OrganizeAction"><span property="agent" typeof="LibrarySystem http://library.link/vocab/LibrarySystem" resource="http://link.library.mst.edu/"><span property="name http://bibfra.me/vocab/lite/label"><a property="url" href="http://link.library.mst.edu/">Missouri University of Science & Technology Library</a></span></span></span></span></div>
Note: Adjust the width and height settings defined in the RDF/HTML code fragment to best match your requirements
Preview
Cite Data - Experimental
Data Citation of the Work Integrated design methodology for isolated floor systems in single-degree-of-freedom structural fuse systems
Copy and paste the following RDF/HTML data fragment to cite this resource
<div class="citation" vocab="http://schema.org/"><i class="fa fa-external-link-square fa-fw"></i> Data from <span resource="http://link.library.mst.edu/resource/KHdPY8GDlOI/" typeof="CreativeWork http://bibfra.me/vocab/lite/Work"><span property="name http://bibfra.me/vocab/lite/label"><a href="http://link.library.mst.edu/resource/KHdPY8GDlOI/">Integrated design methodology for isolated floor systems in single-degree-of-freedom structural fuse systems</a></span> - <span property="potentialAction" typeOf="OrganizeAction"><span property="agent" typeof="LibrarySystem http://library.link/vocab/LibrarySystem" resource="http://link.library.mst.edu/"><span property="name http://bibfra.me/vocab/lite/label"><a property="url" href="http://link.library.mst.edu/">Missouri University of Science & Technology Library</a></span></span></span></span></div>